Model:J-Y-MSC-DC12V/24V/48V-series
|
40A
|
50A
|
60A
|
|||||||
Charge Mode
|
Maximum Power Point Tracking
|
|||||||||
Method
|
3 stages: fast charge(MPPT),constant voltage,floating charge
|
|||||||||
System Type
|
DC12V/24V/48V
|
Automatic recognition
|
||||||||
System Voltage
|
12V system
|
DC9V~DC15V
|
||||||||
|
24V system
|
DC18V~DC30V
|
||||||||
|
48Vsystem
|
DC36V~DC60V
|
||||||||
Soft Start Time
|
12V/24V/48Vsystem
|
≤10S
|
||||||||
Dynamic Response
Recovery Time
|
12V/24V/48Vsystem
|
500us
|
||||||||
Conversion Efficiency
|
12V/24V/48Vsystem
|
≥96.5%,≤99%
|
||||||||
PV Modules Utilization Rate
|
12V/24V/48Vsystem
|
≥99%
|
||||||||
Input Characteristics
|
||||||||||
MPPT Working Voltage and Range
|
12V system
|
DC18V~DC150V
|
||||||||
|
24V system
|
DC34~DC150V
|
||||||||
|
48V system
|
DC65~DC150V
|
||||||||
Low Voltage Input ProtectionPoint
|
12V system
|
DC16V
|
||||||||
|
24V system
|
DC30V
|
||||||||
|
48V system
|
DC60V
|
||||||||
Low Voltage Input RecoveryPoint
|
12V system
|
DC22V
|
||||||||
|
24V system
|
DC34V
|
||||||||
|
48V system
|
DC65V
|
||||||||
Max DC Voltage
|
12V/24V/48Vsystem
|
DC160V
|
||||||||
Input Overvoltage Protection Point
|
12V/24V/48Vsystem
|
DC150V
|
||||||||
Input Overvoltage Recovery Point
|
12V/24V/48Vsystem
|
DC145V
|
||||||||
Max. PV Power
|
12V system
|
570W
|
700W
|
900W
|
||||||
|
24V system
|
1130W
|
1400W
|
1700W
|
||||||
|
48V system
|
2270W
|
2800W
|
3400W
|
||||||
Output Characteristics
|
||||||||||
Selectable Battery Types(Default type is GEL battery)
|
12V/24V/48Vsystem
|
Sealed lead acid, vented, Gel, NiCd battery
(Other types of the batteries also can be defined) |
||||||||
Constant Voltage
|
12V/24V/48Vsystem
|
Please check the charge voltage according to the battery type form.
|
||||||||
Floating Charge Voltage
|
12V/24V/48Vsystem
|
|
||||||||
Over Charge Protection Voltage
|
12V system
|
14.6V
|
||||||||
|
24V system
|
29.2V
|
||||||||
|
48V system
|
58.4V
|
||||||||
Rated Output Current
|
12V/24V/48Vsystem
|
40A
|
50A
|
60A
|
||||||
Current-limiting Protection
|
12V/24V/48Vsystem
|
44A
|
55A
|
66A
|
||||||
Temperature Factor
|
12V/24V/48Vsystem
|
±0.02%/℃
|
||||||||
Temperature Compensation
|
12V/24V/48Vsystem
|
14.2V-(The highest temperature-25℃)*0.3
|
||||||||
Output Ripples(peak)
|
12V/24V/48Vsystem
|
200mV
|
||||||||
Output Voltage StabilityPrecision
|
12V/24V/48Vsystem
|
≤±1.5%
|
||||||||
Display
|
||||||||||
LCD display
|
Input,output parameter and output power etc
(check the LCD display instruction) |
|||||||||
LED display
|
3 LEDs indicates:Fault indicate light,charge indicate light,power source indicate light(check the LED instruction)
|
|||||||||
Software Control through PC(communication port)
|
RS232 (matching) or LAN(optional)
|
|||||||||
Protection
|
||||||||||
Input Low Voltage Protection
|
Check the input characteristics
|
|||||||||
Input Overvoltage Protection
|
Check the input characteristics
|
|||||||||
Input Polarity Reversal Protection
|
yes
|
|||||||||
Output Overvoltage Protection
|
Check the output characteristics
|
|||||||||
Output Polarity Reversal Protection
|
yes
|
|||||||||
Short-circuit Protection
|
Recover after eliminating the Short-circuit fault,no problem for long term Short-circuit
|
|||||||||
Temperature Protection
|
95℃
|
|||||||||
Temperature protection
|
Above 85℃,decrease the output power,decrease 3A per degree.
|
|||||||||
Other Parameters
|
||||||||||
Noise
|
≤40dB
|
|||||||||
Thermal methods
|
Forced air cooling,fan speed rate regulated by temperature,when inner temperature is too low,fan ran slowly or stop;when controller stop working,fan also stop ran.
|
|||||||||
Components
|
World brand raw materials. Compliance with EU standards.All rated temperature ofelectrolytic capacitors not less than 105℃
|
|||||||||
Smell
|
No peculiar smell and and toxic substances.
|
|||||||||
Environment Protection
|
Meet the 2002/95/EC,no cadmium hydride and fluoride
|
|||||||||
Physical
|
||||||||||
Measurement DxWxH(mm)
|
270*185*90
|
|||||||||
N.G(kg)
|
3
|
|||||||||
G.N(kg)
|
3.6
|
|||||||||
Color
|
Blue/Green (optional)
|
|||||||||
Safety
|
CE,RoHS, PSE,FCC
|
|||||||||
EMC
|
EN61000
|
|||||||||
Type of Mechanical Protection
|
IP21
|
|||||||||
Environment
|
||||||||||
Humidity
|
0~90%RH ( no condense)
|
|||||||||
Altitude
|
0~3000m
|
|||||||||
Operating Temperature
|
-20℃ ~ +40℃
|
|||||||||
Storage Temperature
|
-40℃ ~ +75℃
|
|||||||||
Atmospheric Pressure
|
70~106kPa
|